Article Article
Non-destructive Testing Methods for Water Content of Concrete: State-of-the-Art in Japan

Water plays a decisive role in the performance of concrete structures from construction to durability, including the time to finish the concrete substrate, indoor humidity, carbonation, chloride attack, frost damage, alkali-aggregate reactions and corrosion of reinforcement. Recent trends in the life cycle management of infrastructures need methods to measure water content of concrete in reliable, accurate and ease-of-use. This paper reviews studies and applications of methods for water content of concrete structures in terms of their measuring principles, applications and future prospects. Methods of measuring electric resistance and capacitance using embedded or contact electrodes are first dealt with and the results are evaluated with reference to the authors’ experiments. Next, the relationship between relative humidity measurement and water content is discussed both on the borehole method and sheet covering method. Particularly, the impermeable sheet covering and coloring paper methods are easy, non-destructive and applicable to on-site decision for timing the finished construction, while no information is given on the water content inside of the concrete. Finally, the neutron method and direct core sampling method with low abrasion heat are briefly discussed.

References

(1) Japan Society for Civil Engineering, 1989, Handbook of Civil Engineering: Volume 5: Concrete,

(2) Kishitani, K. Editor., 1956, Alkali-Aggregate Reactions, Gihodo Publisher, Tokyo, p 43.

(3) Soshiroda, S., Soshiroda, M. and Tamura, Y., 1955-1956, “Electric Measuring Method for Moisture Content of Mortal and Concrete,” AIJ Proceeding of Architectural Research Meetings, Kanto Chapter, Part 1, 1955, pp 139-142, Part 2, 1955, pp 41-44, Part 3,1956, pp 33-36.

(4) Kasai, Y., Terauchi, Y. and Yokoyama, K., 1962-1963, “Drying of Mortar and Concrete,” AIJ Proceeding of Architectural Research Meetings, Kanto Chapter, Part 1-3, 1962, pp 9-20, Part 4-6, 1963, pp 13-20.

(5) Kasai, Y., Matsui, I., Yuasa, N. and Sato, H., 1995, “Testing Method of Moisture Content in Concrete with a Small Stainless Steel Electrodes,” JCI Proceedings of the Japan Concrete Institute, 17(1), pp 671-676.

(6) Kamada, E., Tabata, M. and Nakano, Y., 1976, “Method of Measuring Moisture Content in Concrete,” JCA Review of the 30th General Meeting, Technical Session, Tokyo, pp 288-292.

(7) Nakane, S., Nagao,K., Ichise, K. and Sangjin, J., 1986, “Method of Measuring Moisture Content in Concrete Structures,” Cement & Concrete, 467, pp 8-14.

(8) Ono, H., Kato, S. and Ohgishi, S., 1993, “Application of Electric Resistance Method on Measurement of Free Water Content in Cement Mortar,” JCA Proceedings of Cement & Concrete, 47, pp 260-265.

(9) Yuasa, N., Kasai, Y. and Matsui, I., 1997, “Measuring Method for Moisture Content in Hardened Concrete Using Electric Properties of a Ceramic Sensor,” Journal of Structural and Construction Engineering, Architectural Institute of Japan, 498, pp 13-20.

(10) Yuasa, N., Kasai, Y. and Matsui, I., 2007, “Comparative Study of the Method Measuring Water Content of Concretes,” Summary of Annual Meeting of JSNDI, pp 127-130

(11) Tadano, K., Koike, M., Tanaka, K. and Hashida, H., 1987, “A Preliminary Study on Thermal Moisture Behavior in Concrete Substrate for Finishes,” AIJ Summaries of Technical Papers of Annual Meeting A, pp 93-94.

(12) Millard, S. G., 1988, “Durability Performance of Slender Reinforced Coastal Defense Units,” SP109-15, American Concrete Institute, pp 339-366.

(13) Yuasa, N., 2012, “Experimental Study on the Meaning of Displayed Value of Microwave Moisture Meter,” 39th Cement and Concrete Conference, pp 75-80.

(14) Shiina, K., 1969, “Internal Humidity and Transformation of Concrete,” JCI Concrete Journal, 7(6), pp 1-11.

(15) Hiraga, T., Miura, I. and Sakamaki, M., 1984, “Method of Measuring Humidity and Moisture Content in Concrete with Color Development Paper,” JCA Review of the 38th General Meeting, Technical Session, Tokyo, pp 198-201.

(16) Yuasa, N., 2013, “Criteria of Water Proofing Construction at the Former JASS8: A “KET Moisture Meter 8%” Story,” Proc. 4th Japan-China-Korea Symp. on Water Proofing Technology, 507, pp 121-128.

(17) Kasai, Y., Matsukawa, T., Sibata, O. and Kamohara, H., 1983-1986, “Test Method for Moisture Contents of concrete by Test Paper,” Summaries of Technical Papers of Annual Meeting of College of Industrial Technology, Nihon University, Part 1, 1983 pp 21-24, Part 2, 1986, pp 29-32.-

(18) Yuasa, N., Kasai, Y., Matsui, I., Henmi, Y. and Satoh, H.,1998, “Evaluation Method for Moisture Condition in Concrete by Using a Humidity Test Paper Pasted on Concrete,” Journal of Finishing Technology, 1(5), pp 1-6.

(19) Bungey, J. H., 1989, Testing of Concrete in Structures, 2nd Edition, Surry University Press, pp 148.

(20) Yuasa, N., Kanematsu, M., Tsuchiya, N. and Kasai, Y., 2010, “Measuring Method for Distribution of Moisture Concrete using Neutron,” Cement Technical Meeting Lecture Summary, 64, pp 134-135.

(21) Yuasa, N., Kasai, Y. and Matsui, I., 1998, “Water Content of Cover Concrete During Drying,” Journal of Structural and Construction Engineering, Architectural Institute of Japan, 509, pp 19-16.

(22) Kutsukake, F., Senbu, O. and Kumagai, T., 1989, “A Measuring Method of Moisture Content on Detached Boundary between Applied Cement Mortar and Concrete Substrate for Epoxy Resin Injecting Repair Work,” AIJ Summaries of Technical Papers of Annual Meeting A, pp 313-314.

(23) Yuasa, N., 2014, “Criteria of Water Proofing Construction at the Former JASS8: A ‘KETT Moisture Meter 8%’ Story,” Water Proofing Journal, 507, pp 70-75.

 

(24) Yuasa, N., 2021, “State-of-the-Art Non-destructive Testing Methods for Moisture Content of Concrete”, Journal of JSNDI, pp 108-115.

Metrics
Usage Shares
Total Views
46 Page Views
Total Shares
0 Tweets
46
0 PDF Downloads
0
0 Facebook Shares
Total Usage
46