Implementation of Computerized Radiography in the Work Place
Authors: Conference: Publication Date: 27 July 2015Testing Method:
This paper is presented as an approach to implement the Computerized Radiography Inspection method into a current process of Radiographic Inspection. An overview of the implementation and a recommended form to capture On the Job Training is presented. A brief overview of the radiographic inspection process, an example of a Force Field Analysis and an action plan for incorporating this process will be discussed.
References
- ASTM E 2002 Standard Practice for Determining Total Image Unsharpness in Radiology
- ASTM E 2007 Standard Guide for Computed Radiology
- ASTM E 2033 Standard Practice for Computed Radiology
- ASTM E 2339 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)
- ASTM E 2445 Standard Practice for Qualification and Long-Term Stability of Computed Radiology Systems
- ASTM E 2446 Standard Practice for Classification of Computed Radiology Systems
- ASTM E 2660 Standard Digital Reference Images for Investment Steel Castings for Aerospace Applications
- EN462-5 Duplex Wire Gage
- MAI PCC-1 Material Affordability Initiatives Guidelines Document Task 4 Final 10-4-10
- P&W NDTQ P&W NDT Qualification & Certification Specification
- DRM Master P&W Digital Radiography Master
- P3TF38 GE Aircraft Engines Specification for Non-Film Radiological Inspection
- RRP 58009 Rolls Royce AMS for Digital Radiography
- ISBN 1-57117-120-7 Radiographic Testing Classroom Training Book Written for ASNT by Jean Staton ANSI.ASNT CP 105-2011 Topical Outlines for Qualification of Nondestructive Testing Personnel