This paper explains a new gravimetric technique,
the fixed points technique, which assesses
moisture in masonry and compares the results
with results obtained by another gravimetric
technique, the weighing technique. Measurements
using both techniques were taken at three
different heights from the floor and repeated after
one and two months. The results were then qualitatively
compared, since the two techniques give
two different parameters: the actual percentage of
water content of the wall using the weighing
technique versus the percentage of water content
of a terracotta probe (in the case of the fixed
points technique). Using the weighing technique
as a reference, the analysis shows that the fixed
points technique applied to a wall shows the same
trends for the water content of the wall, both as a
whole (a parameter that is useful to know the
general behavior of the wall) and for values
measured at different depths, (which are useful in
determining the source of water in the wall).
UNI, UNI 11085:Beni Culturali – Materiali Lapidei Naturali ed Artificiali.
Determinazione del Contenuto di Acqua. Metodo Ponderale, Ente Nazionale
Italiano di Unificazione, Rome, Italy, 2003.
Capitani, D., N. Proietti, M. Gobbino, L. Soroldoni, U. Casellato, M.
Valentini and E. Rosina, “An Integrated Study for Mapping the Moisture in
an Ancient Damaged Wall Painting,” Analytical Bioanalytical Chemistry,
No. 7, 2009, pp. 2245–2253.
Cruciani Fabozzi, G., E. Rosina and M. Valentini, “Thermography and
Gravimetric Tests in Moisture Analysis – Atti del 20° Congresso nazionale
Metodi Chimici, Fisici e Biologici per la Salvaguardia dei Beni Culturali,”
CISTeC-Università di Roma “La Sapienza”-Progetto finalizzato Beni culturali
CNR, Roma, 18 October 1998.
Maggi, V., “Integrazione di due Metodi per la Misurazione dell’umidità
nelle Strutture Murarie,” Thesis, Politecnico di Milano-Facoltà di Architettura,
relatore: G. Cruciali Fabozzi, Correlatore: E. Rosina, M. Valentini, 1998.
UNI, UNI 11085:Beni Culturali – Materiali Lapidei Naturali ed Artificiali.
Determinazione del Contenuto di Acqua. Metodo Ponderale, Ente Nazionale
Italiano di Unificazione, Rome, Italy, 2003.
Valentini, M., “Una Metodologia Poco Invasiva per la Misura del Contenuto
di Acqua delle Murature,” Monitoraggio e Conservazione Programmata,
25 November 2005, Torino, Italy, pp. 168–173.
Valentini, M.,“Il Metodo dei Punti Permanenti di Misura,” Il Canopoleno di
Sassari da Casa Professa a Pinacoteca, Storia e restauri, Silvana editore,
2009, pp. 78–83.