Design and Performance of a Broadband 10 MHz Transducer for Elevated Temperature, Leave-in-Place Applications

This paper describes the novel design of an ultrasonic normal beam transducer for prolonged use in elevated temperature environments. Through the use of a carbon/carbon composite backing layer, prolonged exposure to elevated temperature had minimal effect on transducer performance. The conductive nature of the carbon/carbon allowed for an innovative electrical coupling technique. A clamping mechanism combined with the use of an annealed gold quarter wave matching layer allowed for jointfree, dry coupling. This simple design allows for easy field assembly and eliminates temperature dependencies in the acoustic coupling. The transducer was tested initially at room temperature for reference data. Further tests after 100+ h of exposure to a 351 K environment showed little overall change in the transducer performance. The transducer showed consistent –6 dB bandwidths on the order of 54 to 67%, along with negligible change in centerline frequency. The insertion loss as a function of temperature showed an increase from approximately 6.8 to 8.5 dB over a temperature range from 298 to 358 K. Regression lines show bandwidth changes of –0.01% per 1 K and insertion loss changes of 0.03 dB per 1 K. These results show potential use for a transducer of this design at even higher temperatures.

References
Cannata, J.M., T.A. Ritter, W. Chen, R.H. Silverman and K.K. Shung, “Design of Efficient Broadband Single-Element (20-80 MHz) Ultrasonic Transducer for Medical Imaging Applications,” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 50, 2003, pp. 1548–1557. Donaldson, Steven L. and Daniel B. Miracle, ASM Handbook, Vol. 21, Composites, Materials Park, Ohio, ASM International, 2001. Lynnworth, L.C., Ultrasonic Measurements for Process Control, Boston, Academic Press, 1989. McNab, A., K.J. Kirk and A. Cochran, “Ultrasonic Transducers for High Temperature Applications,” IEE Proceedings: Science, Measurement & Technology, Vol. 145, 1998, pp. 229–236. Nascimento, V.M., V.L. Nantes Button, J. Maia, E. Costa and J.V. Oliviera, “Influence of Backing and Matching Layers in Ultrasound Transducer Performance,” SPIE Medical Imaging: Ultrasonic Imaging and Signal Processing, Vol. 5035, 2003, pp. 86–96. Tittmann, B.R. and M. Aslan, “Ultrasonic Sensors for High Temperature Applications,” Japan Journal of Applied Physics, Vol. 38, 1999, pp. 3011–3013. Tittmann, B.R., M. Bhardwaj, L. Vandervalk and I. Neeson, “Non Contact Ultrasonic NDE of Carbon/Carbon Composite,” Proceedings of American Ceramics Society, Vol. 20, 1999, pp. 325–332.
Metrics
Usage Shares
Total Views
13 Page Views
Total Shares
0 Tweets
13
0 PDF Downloads
0
0 Facebook Shares
Total Usage
13