The article describes an effective method of measurement for enhancing the repeatability in
the experimental determination of electrical potential drop for the evaluation of materials.
In the present approach, an averaging scheme is adopted for measuring the potential drop
using a DC four-point-probe measuring system, where the associated probe contact
distances on the material surface are adjusted in successive measurements by refreshing
the individual contacts of the spring-loaded probes to the measuring surface. Statistical considerations
are discussed in the context of repeatability of results using this method. Finally,
the application of the method is demonstrated and discussed for a practical problem
of interest, namely, the evaluation of rear-wall flaws (cracks and slots) in thick-walled
structures. In an attempt to verify the accuracy, measured results are compared with the
corresponding finite-element predictions of the potential drop. Results of the present study
and also the comparative analysis firmly establish the appropriateness as well as reliability
of the present potential-drop measuring system for obtaining repeatable measurements in
the evaluation of materials.
1. R. K. Stanley, P. O. Moore, and P. McIntire (eds.). Special Nondestructive Testing Methods, vol. 9 of
Nondestructive Testing Handbook, 2nd ed. American Society for Nondestructive Testing, Columbus,
OH (1995).
2. S. S. Udpa and P. O. Moore (eds.). Electromagnetic Testing, vol. 5 of Nondestructive Testing Handbook,
3rd ed. American Society for Nondestructive Testing, Columbus, OH (2004).
3. N. Bowler and Y. Huang. Electrical conductivity measurement of metal plates using broadband eddycurrent
and four-point methods. Meas. Sci. Technol. 16:2193 (2005).
4. N. Bowler and Y. Huang. Model-based characterization of homogeneous metal plates by four-point
alternating current potential drop measurements. IEEE Trans. Magnetics 41(6):2102 (2005).
5. Y. Ju, B. F. Ju, and M. Saka. Microscopic four-point atomic force microscope probe technique for local
electrical conductivity measurement. Rev. Sci. Instrum. 76(8):086101 (2005).
6. T. V. Venkatasubramanian and B. A. Unvala. An AC potential drop system for monitoring crack
length. J. Phys. E: Sci. Instrum. 17:765 (1984).
7. W. D. Dover, F. D. W. Charlesworth, K. A. Taylor, R. Collins, and D. H. Michael. The Use of A-C
Field Measurements to Determine the Shape and Size of a Crack in a Metal. In Eddy-current Characterization
of Materials and Structures, ASTM STP 722, G. Birnbaum and G. Free (eds.), p. 401 (1981).
American Society for Testing and Materials, Philadelphia.
8. H. H. Johnson. Calibrating the electric potential method for studying slow crack growth. Mat. Res.
Stand. 5(1):442 (1965).
9. M. Saka, D. Hirota, H. Abe´, and I. Komura. NDE of a 3-D surface crack using closely coupled probes
for DCPD technique. J. Press. Vess. Technol. (Trans ASME) 120(4):374 (1998).
10. M. Saka, A. Oouchi, and H. Abe´. NDE of a crack by using closely coupled probes for DCPD technique.
J. Press. Vess. Technol. (Trans ASME) 118(2):198 (1996).
11. H. Liu, M. Saka, H. Abe´, I. Komura, and H. Sakamoto. Analysis of interaction of multiple cracks in a
direct current field and nondestructive evaluation. J. Appl. Mech. (Trans ASME) 66(2):468 (1999).
12. O. Buck, R. B. Thompson, and D. K. Rehbein. The interaction of ultrasound with contacting asperities:
Applications to crack closure and fatigue crack growth. J. Nondestr. Eval. 4(3=4):203 (1984).
13. M. Saka, E. Schneider, and P. Hoeller. A new approach to detect and size closed cracks by
ultrasonics. Res. Nondestr. Eval. 1(2):65 (1989).
14. W. Elber. Damage Tolerance in Aircraft Structures, ASTM STP 486. p. 230. American Society for Testing
and Materials, Philadelphia (1971).
15. S. R. Ahmed and M. Saka. A sensitive ultrasonic approach to NDE of tightly closed small cracks.
J. Press. Vess. Technol. (Trans ASME) 120(4):384 (1998).
16. S. R. Ahmed and M. Saka. Crack length independent evaluation of depth of small surface cracks. Mat.
Eval. 60(4):535 (2002).
17. S. R. Ahmed and M. Saka. Influence of wall thickness on the ultrasonic evaluation of small closed
surface cracks and quantitative NDE. J. Nondestr. Eval. 21(1):9 (2002).
18. R. Clark, W. D. Dover, and L. J. Bond. The effect of crack closure on the reliability of NDT predictions
of crack size. NDT International 20(5):269 (1987).
19. M. Saka, D. Hirota, and H. Abe´. Enhancement of sensitivity of the potential drop technique for sizing
a crack by using closely coupled probes. Proceedings of the 14th World Conference on NDT, Vol. 3.
p. 1659, Oxford & IBH Publishing Co. Pvt. Ltd., New Delhi (1996).
20. MSc Marc User’s Guide. MSc Software Corporation, Santa Ana, CA (2003).
21. H. W. Coleman and W. G. Steele. Experimentation and Uncertainty Analysis for Engineers, pp. 26–27.
(1989). John Wiley & Sons, New York.