Four-point direct-current potential drop techniques are well-suited for accurate, nondestructive
measurement of material conductivity (or resistivity). From measurements of potential
drop on a large metal plate, the electrical conductivity of the plate can be inferred if the
thickness of the plate and the dimensions of the probe are known. In this work, an
expression for the voltage measured by a four-point probe in contact with a large metal
plate of arbitrary thickness is derived from an analytic series representation of the electric
field in the plate. The position of the voltage pickup points is permitted to be offset with
respect to the current injection points, allowing analysis of colinear, rectangular, and
square-head probes. Analytical asymptotic expressions are derived in the limiting cases
of plates that are thin or thick with respect to the dimensions of the probe. The range of plate
thicknesses for which the asymptotic expressions are valid is determined as a function of
relevant probe dimensions. The results of this study provide a useful guide in selecting
the most appropriate arrangement of probe points for measurement of the electrical conductivity
of large metal plates, depending on the level of accuracy required. Theory is compared
with experimental data for measurements made with colinear probes on a variety
of metal plates and very good agreement is obtained.
1. R. K. Stanley, P. O. Moore, and P. McIntire (eds.). Nondestructive Testing Handbook, 2nd ed., vol. 9,
Special Nondestructive Testing Methods. American Society for Nondestructive Testing, Columbus,
OH (1995).
2. A. C. Lynch, A. E. Drake, and C. H. Dix. Measurement of eddy-current conductivity. IEE Proc. A
130:254 (1983).
3. G. R. Metcalfe. The use of eddy current flaw detectors with meter display for measuring the conductivity
of aluminum alloy structures. British J. NDT 30:164 (1988).
4. N. Bowler and Y. Huang. Electrical conductivity measurement of metal plates using broadband eddycurrent
and four-point methods. Meas. Sci. Technol. 16:2193 (2005).
5. H. Suhr and T. W. Guettinger. Error reduction in eddy current conductivity measurements. British J.
NDT 35:634 (1993).
6. F. Yu and P. B. Nagy. Simple analytical approximations for eddy current profiling of the near-surface
residual stress in shot-peened metals. J. Appl. Phys. 96: 1257 (2004).
7. D. K. Schroder. Semiconductor Material and Device Characterization. Wiley, New York (1998).
8. J. M. Reynolds. Introduction to Applied and Environmental Geophysics. Wiley, Chichester, UK
(1997).
9. D. S. Parasnis. Principles of Applied Geophysics, 5th ed. Chapman and Hall, London (1997).
10. N. Bowler. Electric field due to alternating current injected at the surface of a metal plate. J. Appl.
Phys. 96:4607 (2004).
11. N. Bowler and Y. Huang. Four-point alternating current potential drop measurements on metal plates:
experiment and interpretation. Center for Nondestructive Evaluation, Iowa State University, Ames,
Iowa 2005. Unpublished.
12. A. Uhlir, Jr. The potentials of infinite systems of sources and numerical solutions of problems in
semiconductor engineering. Bell Syst. Tech. J. 34:105 (1955).
13. M. Abramowitz and I. A. Stegun (eds.). Handbook of Mathematical Functions with Formulas, Graphs,
and Mathematical Tables. Dover, New York (1972).
14. S. S. Udpa and P. O. Moore (eds.). Nondestructive Testing Handbook, 3rd ed., vol. 5, Electromagnetic
Testing. American Society for Nondestructive Testing, Columbus (2004).
15. N. Bowler and Y. Huang. Model-based characterization of homogeneous metal plates by four-point
alternating current potential drop measurements. IEEE Trans. Mag. 41:2102 (2005).